The Cummins Onan QG 5500 is the default built-in generator for Class A and large Class C motorhomes. 5,500 watts, 67 dBA, runs one or two air conditioners per Cummins. But is it reliable? What does it really cost to run? And should you buy the gasoline or propane version? This review covers published specs, real fuel consumption, common problems, and the repair-vs-replace decision. Compare portable options.

Motorhome RV parked at sunset
Image: Pexels (free commercial license)

Affiliate disclosure: RV Solar Power Guide is reader-supported. When you buy through links on this page, we may earn a commission at no extra cost to you. Our picks come from comparing verified specs and price. We don't accept payment for placement.

Power

5,500W at 120V (45.8A). Spec sheet: one 13.5K or two 11K BTU ACs.

Noise

67 dBA at 10 ft, half load (spec sheet A-1425). NPS: 60 dBA at 50 ft.

Fuel use

Gas: 0.6 gal/hr half load, 0.9 full. LP: 0.8/1.1 gal/hr. Per dealer specs.

Check Onan 5500 Parts & Accessories on Amazon

The complete QG 5500 is sold through RV dealers; Amazon carries parts, filters, and accessories.

01Onan 5500 specifications

Specs below are compiled from authorized Cummins Onan dealer listings (Camping World, Norwall, AP Electric), checked October 2026. Cummins publishes full spec sheets through dealers; model variants may differ slightly. The QG 5500 comes in gasoline and LP (propane) variants with slightly different specs.

Gasoline model (5.5HGJAB-6755, EVAP)

  • Power: 5,500W, 120V single-phase, 45.8A, 60 Hz
  • Engine: Cummins Onan OHV EH65V, 4-cycle 90° V-twin, 39.8 cu in (653cc)
  • RPM: 2400 (low speed for reduced noise and wear)
  • Fuel system: EVAP emissions-compliant gasoline (a separate EFI fuel-injected variant also exists; confirm fuel system on the data tag)
  • Fuel consumption: 0.6 gal/hr at half load, 0.9 gal/hr at full load
  • Noise: 67 dB(A) at 10 ft (3 m), half load (per Cummins spec sheet A-1425)
  • Weight: 279 lbs (127 kg, per Cummins spec sheet A-1425)
  • Dimensions: 33.6" L x 22.2" W x 16.7" H
  • Oil capacity: 2.0 quarts including filter
  • Circuit breakers: (2) 30A
  • Warranty: 3-year limited + lifetime drive warranty

LP / Propane model (5.5HGJAB-1119)

  • Power: 5,500W, 120V single-phase, 45.8A
  • Fuel consumption: 0.8 gal/hr at half load, 1.1 gal/hr at full load
  • Noise: 67 dB(A) at 10 ft (3 m), half load (per Cummins spec sheet A-1425; same for gas and LP)
  • Weight: 279 lbs (127 kg, per Cummins spec sheet A-1425; same for gas and LP)
  • Emissions: Meets California CARB 2024 SORE standards (50-state compliant)
  • Other specs: Same dimensions, engine, and warranty as gasoline model

02Gas vs LP: which Onan 5500 to choose

Choose gasoline if: your RV already has a large gasoline tank (most Class A motorhomes do), you want the lowest fuel cost per hour, and you prefer EFI's resistance to stale-fuel starting problems.

Choose LP if: your RV is propane-heavy (common in smaller Class Cs), you need California CARB 2024 compliance, you want potentially slightly lower noise, or you store the RV for long periods (propane never goes stale). The trade-off is higher fuel consumption: 0.8 vs 0.6 gal/hr at half load.

Fuel cost illustration (using assumed prices, not current pump prices): at $3.50/gallon gasoline, half-load costs about $2.10/hour (0.6 x 3.50). At $3.00/gallon propane, about $2.40/hour (0.8 x 3.00). Neither is cheap; the Onan 5500 is for comfort, not economy.

03Air conditioner compatibility

Cummins' official spec sheet (A-1425) states air conditioner starting capability as:one 13,500 BTU air conditioner with 3,000W base load, or two 11,000 BTU air conditioners with 1,500W base load, at 100°F and 500 ft elevation. Cummins' product page more broadly says the QG 5500 "runs one or two air conditioners with power to spare." Many dealers describe it as handling two 15,000 BTU units, but that exceeds what the official spec sheet documents.

Actual compatibility depends on the specific AC units, compressor running current, startup surge, other simultaneous loads, ambient temperature, altitude, and generator condition. BTU rating alone does not determine electrical draw. If your ACs are struggling, have an RV technician measure the actual running and starting amps. Do not assume every two-AC setup will work in every RV.

Ownership guide: problems, maintenance & costs

Common problems and warning signs

Won't start after storage: The #1 issue. On older carbureted models, stale gasoline gums the carburetor. EFI models are more resistant but not immune. Fix: run the generator under load for 30 minutes monthly. If it won't start, check fuel supply, oil level (low-oil shutdown), and read the fault code from the self-diagnostic system.

Starts then shuts down: Check the fault code blink pattern on the control panel. Common causes: low oil, overheating (blocked cooling air intake), or overload. The microprocessor control protects against overcrank, overload, over/under frequency, and starter faults.

Low power output: On high-hour units (2,000+ hours), brush and slip ring wear reduces output. This is a serviceable repair but requires opening the generator end.

When to call a professional: Any fuel system work beyond the filter, electrical diagnostics involving the stator/rotor, or if fault codes indicate internal failure. Onan generators are not DIY-friendly beyond basic maintenance.

Maintenance schedule

Typical guidance: change oil and filter every 150 hours or annually (2.0 quarts including filter); confirm the interval in your exact model's operator manual, as it varies by spec. Replace the air filter element as needed. Inspect the spark-arrestor muffler. Exercise monthly under load for about 30 minutes (Cummins recommends running under load, not just idling). Keep the cooling air intake clear.

Buying used: inspection checklist

1. Get the hour meter reading. Under 1,000 hours is low; 1,000-2,000 is moderate; over 2,000 needs a thorough check. 2. Find the model and spec number on the data tag (e.g., 5.5HGJAB-6755 + spec letter). You need both for parts. 3. Start it cold and listen for knocking, smoking, or rough running. 4. Load test: run both ACs and check voltage stability. 5. Check for oil leaks around the base and 6. Ask for maintenance records. A neglected Onan is an expensive Onan.

Repair vs replace

Repair if: compression is good, power output is clean, and the problem is fuel system, starter, control board, or brushes. These are all replaceable at reasonable cost.

Replace if: the engine needs rebuilding, stator/rotor windings are damaged, or the repair estimate exceeds 50% of a new unit installed. A new QG 5500 plus professional installation runs several thousand dollars, so major repairs are often the economical choice.

Altitude derating

Generator output drops with altitude because thinner air reduces engine power. Cummins spec sheet A-1425 specifies approximately 3.5% power loss per 1,000 feet above sea level, plus 1% loss per 10°F above 77°F. At 5,000 feet, expect about 17% less power (roughly 4,550W instead of 5,500W). At 8,000 feet, about 28% less (roughly 3,960W). If you camp at altitude regularly, this can turn a comfortable two-AC setup into a marginal one. Plan loads accordingly.

Runtime by fuel supply

The Onan 5500 has no built-in tank; it draws from your RV's fuel system. Estimates below assume usable fuel (not total tank capacity) and steady half-load operation. As arithmetic: 10 gallons / 0.6 gal/hr = ~16.7 hours; 10 / 0.9 = ~11 hours. For LP at 0.8 gal/hr: a standard 20-lb propane cylinder holds about 4.7 gallons (20 lbs / 4.24 lbs per gallon), so 4.7 / 0.8 = ~5.9 hours. A cylinder may not deliver its full rated capacity in cold weather or at high draw rates. These are estimates; actual consumption varies with load, temperature, and altitude.

Common fault codes

On many QG models, read fault codes by pressing the Stop button on the control panel 3 times within 5 seconds; the LED blinks the code. Procedure varies by model year, so confirm in your operator manual. Commonly reported codes include:

  • Code 3: Service check needed (first-level warning)
  • Code 15: Under-frequency (generator slowed under load)
  • Code 36: Engine stopped unexpectedly (check fuel, oil, air)

DIY: check fuel level (generator pickup is higher than engine pickup; below 1/4 tank can cause shutdown), oil level, and air filter. Call a professional for recurring codes, internal electrical faults, or anything involving the stator, rotor, or control board.

Safety

The Onan 5500 is permanently installed in a ventilated RV compartment with sealed exhaust routing. Never modify the exhaust system. Never run it with the compartment door open in a way that allows exhaust to enter the living space. Install and maintain CO detectors inside the RV. The generator's own safety shutdowns (low oil, overspeed, overload) protect the machine, not you; safe installation and CO detectors protect you.

04Strengths and trade-offs

Strengths

  • 5,500W; Cummins spec sheet documents one 13,500 BTU or two 11,000 BTU ACs
  • Fuel-injected (EFI) variant resists stale-fuel starting problems common in carbureted units
  • 67 dBA at 10 ft per spec sheet; Cummins states NPS 60 dBA at 50 ft compliance
  • Self-diagnostic system with fault codes simplifies troubleshooting
  • 3-year limited warranty plus lifetime drive warranty
  • Proven platform with wide parts availability and dealer service network

Trade-offs

  • 279 lbs and permanently installed; not portable, professional installation required
  • 0.6-0.9 gal/hr fuel consumption adds up; not economical for light loads
  • New unit plus installation costs several thousand dollars
  • Older carbureted models prone to stale-fuel starting issues if not exercised monthly
  • Altitude derating (~3.5% per 1,000 ft) can make two-AC operation marginal at elevation
  • DIY repair limited; most internal work needs a qualified technician

Frequently asked questions

How many watts is the Onan 5500 generator?

5,500 watts at 120V single-phase (45.8 amps), running at 2400 RPM. Spec sheet: one 13,500 BTU or two 11,000 BTU ACs.

How much fuel does an Onan 5500 use per hour?

Gasoline: about 0.6 gal/hr at half load, 0.9 gal/hr at full load. LP: about 0.8 gal/hr at half load, 1.1 gal/hr at full load. Per dealer specs; actual use varies.

How loud is the Onan 5500 generator?

67 dB(A) at 10 feet under half load per spec sheet A-1425. Cummins states NPS 60 dB(A) at 50 feet compliance.

What is the difference between Onan 5500 gas and LP models?

Gas (5.5HGJAB-6755, EVAP) and LP (5.5HGJAB-1119): 0.6/0.9 and 0.8/1.1 gal/hr, 67 dBA, 279 lbs per spec sheet A-1425. A separate EFI variant also exists.

Can the Onan 5500 run two air conditioners?

Spec sheet: one 13,500 BTU or two 11,000 BTU ACs. Dealer claims of two 15,000 BTU units exceed the official spec.

What are common problems with the Onan 5500?

Failure to start after storage (stale fuel), fault-code shutdowns, low-oil shutdown, and brush/slip ring wear on high-hour units. Monthly exercise under load prevents most issues.

How do I find my Onan 5500 model and spec number?

On the data tag inside the generator compartment door. Format like '5.5HGJAB-6755' plus a spec letter. You need both numbers when ordering parts.

How much does an Onan 5500 weigh?

279 lbs (127 kg) per spec sheet A-1425. Dimensions: 33.6 x 22.2 x 16.7 inches. Permanently installed, not portable.

What is the warranty on the Onan 5500?

3-year limited (parts/labor first 2 years, major drivetrain parts year 3) plus lifetime drive warranty. 90-day free minor adjustment policy included.

Should I repair or replace my old Onan 5500?

Repair if compression and power output are good and the issue is fuel, starter, controls, or brushes. Replace if the engine needs rebuilding or windings are damaged, or repair exceeds 50% of new installed cost.